Model/Brand/Package
Category/Description
Inventory
Price
Data
-
Category: Industrial Relay/UniversalDescription: Moeller81531+$436.411210+$425.026650+$416.2983100+$413.2624200+$410.9855500+$407.94961000+$406.05222000+$404.1547
-
Category: Industrial Relay/UniversalDescription: 10A Side or top mounted maximum cable capacity 2 x 2.5mm2 # # # Moeller DIL E 3 and 4 series small contactors and control relays51001+$73.953110+$70.7377100+$70.1589250+$69.7088500+$69.00141000+$68.67992500+$68.22975000+$67.8439
-
Category: Industrial Relay/UniversalDescription: 10A Side or top mounted maximum cable capacity 2 x 2.5mm2 # # # Moeller DIL E 3 and 4 series small contactors and control relays36191+$126.143510+$122.852850+$120.3299100+$119.4524200+$118.7943500+$117.91681000+$117.36832000+$116.8199
-
Category: Industrial Relay/UniversalDescription: Overload relay, used for MEM packaged starter motors. This series of overload relays is suitable for use with MEM Eaton packaged starters. ### MEM Eaton86901+$423.340310+$412.296650+$403.8298100+$400.8849200+$398.6761500+$395.73121000+$393.89052000+$392.0499
-
Category: Industrial Relay/UniversalDescription: DILM The 3-phase X Start series of contactors is Moeller's latest generation of contactors, overloads, and relays, based on the tried and tested DIL series. This generation of modular components benefits from advances in motor switching and control technology, bringing many other advantages to users. All contactors are modular and have a universal design. This series is extremely durable, capable of handling all needs, with anti-interference function and control circuit stability. Even when used in conjunction with PLC, the frame size required for magnetic field system electronic power regulation to DC contactors is very small, which allows AC and DC devices to have the same size. This allows for the direct parallel placement of AC and DC contactors. Three types of normally open main contact 12A DC contactors have an electronic driver, which eliminates the need for coupling relays. All DC contactors with a current not exceeding 150A have built-in suppression circuits. When wiring different cross-sections, a junction box with two coupling areas ensures connection integrity and reduces wiring errors. Moeller X starting range94301+$481.640710+$469.076250+$459.4433100+$456.0928200+$453.5799500+$450.22941000+$448.13532000+$446.0412
-
Category: Industrial Relay/UniversalDescription: DILM Auxiliary modules (2-pole) These modules are inserted into the front of the DILM motor contactor to provide additional contacts DILM32 auxiliary contacts, which are used in conjunction with DILM7 to DILM32 contactors. DILM150 auxiliary contact, used with DILM40 to DILM150 contactors, rated current 3A (AC 15) at 400V # # Moeller X starting range45651+$61.082310+$58.4265100+$57.9485250+$57.5767500+$56.99241000+$56.72682500+$56.35505000+$56.0363
-
Category: Industrial Relay/UniversalDescription: DILM The 3-phase X Start series of contactors is Moeller's latest generation of contactors, overloads, and relays, based on the tried and tested DIL series. This generation of modular components benefits from advances in motor switching and control technology, bringing many other advantages to users. All contactors are modular and have a universal design. This series is extremely durable, capable of handling all needs, with anti-interference function and control circuit stability. Even when used in conjunction with PLC, the frame size required for magnetic field system electronic power regulation to DC contactors is very small, which allows AC and DC devices to have the same size. This allows for the direct parallel placement of AC and DC contactors. Three types of normally open main contact 12A DC contactors have an electronic driver, which eliminates the need for coupling relays. All DC contactors with a current not exceeding 150A have built-in suppression circuits. When wiring different cross-sections, a junction box with two coupling areas ensures connection integrity and reduces wiring errors. Moeller X starting range16721+$588.563810+$567.912450+$565.3310100+$562.7496150+$558.6193250+$555.0053500+$551.39131000+$547.2610
-
Category: Industrial Relay/UniversalDescription: DILM The 3-phase X Start series of contactors is Moeller's latest generation of contactors, overloads, and relays, based on the tried and tested DIL series. This generation of modular components benefits from advances in motor switching and control technology, bringing many other advantages to users. All contactors are modular and have a universal design. This series is extremely durable, capable of handling all needs, with anti-interference function and control circuit stability. Even when used in conjunction with PLC, the frame size required for magnetic field system electronic power regulation to DC contactors is very small, which allows AC and DC devices to have the same size. This allows for the direct parallel placement of AC and DC contactors. Three types of normally open main contact 12A DC contactors have an electronic driver, which eliminates the need for coupling relays. All DC contactors with a current not exceeding 150A have built-in suppression circuits. When wiring different cross-sections, a junction box with two coupling areas ensures connection integrity and reduces wiring errors. Moeller X starting range95491+$340.111410+$331.238950+$324.4367100+$322.0707200+$320.2962500+$317.93021000+$316.45142000+$314.9727
-
Category: Industrial Relay/UniversalDescription: ZB Overload relay protects the motor from phase errors or damage caused by overload. When directly connected to the contacts, it provides short-circuit protection suitable for Atex motors. The single-phase sensitivity complies with IEC/EN 60947. When the overload relay is not directly installed on the contactor or multiple contactors are used, a bracket (only stock number 493-0488 \ - ZB32) needs to be installed. Note that ZB12 has 5 pins and ZB32 has 4 pins. ###Recognize CCC # # # ZB overload relay32641+$450.217010+$438.472250+$429.4678100+$426.3359200+$423.9869500+$420.85501000+$418.89752000+$416.9400
-
Category: power relayDescription: EATON CUTLER HAMMER D7PF1AA Power Relay, SPDT, 120VAC, 20A, D7 Series, Socket56431+$161.042610+$156.841450+$153.6206100+$152.5003200+$151.6601500+$150.53981000+$149.83962000+$149.1394
-
Category: Industrial Relay/UniversalDescription: DILA The auxiliary contact module can be used with DILA contactor relays or DILM7 to DILM32 motor contactors # # Moeller X starting range81531+$149.943910+$146.032350+$143.0334100+$141.9904200+$141.2080500+$140.16501000+$139.51302000+$138.8611
-
Category: Industrial Relay/UniversalDescription: Auxiliary Contact Module Front Installation Rated Current 10A Side or Top Installation Maximum Cable Capacity 2 x 2.5mm2 # # # Moeller DIL E 3 and 4 Series Small Contactors and Control Relays65041+$192.891810+$187.859850+$184.0020100+$182.6601200+$181.6538500+$180.31191000+$179.47322000+$178.6346
-
Category: Industrial Relay/UniversalDescription: DILER Small contactor relays with rated current of 10A only for AC or DC control coils, equipped with protective surface mounting or DIN rail mounting, maximum rated voltage of 500V AC/250V DC size: height x width x thickness 58 x 45 x 52 mm # # # Moeller DIL E 3 and 4 series small contactors and control relays42071+$326.146910+$317.638750+$311.1158100+$308.8469200+$307.1453500+$304.87651000+$303.45842000+$302.0404
-
Category: power relayDescription: EATON CUTLER HAMMER XRU1D24 Terminal block relay, 24VDC, 1PDT, screw, DIN rail installation53271+$271.708210+$264.620250+$259.1860100+$257.2959200+$255.8782500+$253.98811000+$252.80682000+$251.6254
-
Category: Relays and accessoriesDescription: SmartWire-DT PKE The SmartWire DT PKE communication and function module is used for installation on PKE12, 32, and 65 motor protection circuit breakers, motor starters, and contactors. ### Moeller PKE Motor Protective Circuit Breakers61791+$383.836710+$373.823550+$366.1468100+$363.4766200+$361.4740500+$358.80381000+$357.13502000+$355.4661
-
Category: power relayDescription: EATON CUTLER HAMMER D7PF3AA RELAY, 3PDT, 120VAC, 28VDC, 15A50051+$218.038910+$212.350950+$207.9901100+$206.4733200+$205.3357500+$203.81891000+$202.87092000+$201.9229
-
Category: power relayDescription: EATON CUTLER HAMMER 9575H3A000 Universal relay, DPDT, 120V/60HZ, 110V/50Hz20191+$1433.809310+$1420.774725+$1414.257450+$1407.7400100+$1401.2227150+$1394.7054250+$1388.1881500+$1381.6708
-
Category: power relayDescription: EATON CUTLER HAMMER D7PF4AT1 Power relay, 24VDC, 15A, 4PDT, DIN rail installation18391+$186.657710+$181.788350+$178.0552100+$176.7567200+$175.7828500+$174.48431000+$173.67282000+$172.8612
-
Category: power relayDescription: EATON CUTLER HAMMER XRU1D120U Terminal block relay, 120VAC/110VDC, 1PDT, DIN rail installation57331+$364.473010+$354.965050+$347.6755100+$345.1400200+$343.2384500+$340.70301000+$339.11832000+$337.5336
-
Category: Industrial Relay/UniversalDescription: Auxiliary contacts; Series: DILM25048571+$158.941510+$154.795250+$151.6164100+$150.5107200+$149.6814500+$148.57581000+$147.88472000+$147.1937
-
Category: Safety typeDescription: ESR5 Eaton's ESR5 safety relay is designed to constantly monitor signals from safety devices and quickly and reliably shut down in emergency situations. Suitable for applications that meet the highest safety requirements, compliant with EN 954-1, EN ISO 13849-1 (up to PL e), and IEC 62061 (up to SILCL 3). ESR5 safety relays are compatible with various safety devices, such as emergency stops, rope switches, dual hand control consoles, light curtains (OSSD), starter door devices, and safety switches. Used for the highest safety requirements, compliant with EN 954-1 EN ISO 13849-1, IEC 62061, and EC 61508, suitable for the global market, with UL, cUL certification and T Ü V Rhineland functional safety certification. Suitable for EN 60204 stop category 0 or 1 plug-in screw terminal blocks, can be used for quick and accessible replacement of delayed and non delayed contact extensions, suitable for various applications # # # Standard UL, cULus, T Ü V. # # Safety Relays53381+$1868.398410+$1851.413025+$1842.920250+$1834.4275100+$1825.9348150+$1817.4421250+$1808.9494500+$1800.4566
-
Category: Industrial Relay/UniversalDescription: EMR5 The professional Eaton current monitoring relay series comes from the EMR5 series. The main function of a relay is to monitor single-phase AC and DC networks. Relay design is used for a wide range of applications covering electrical switchgear technology, such as multifunctional 3-phase monitors and ground leakage monitors. Phase sequence detection, phase fault detection, LED status indication, Eaton monitoring relay71001+$1859.720510+$1842.814025+$1834.360750+$1825.9074100+$1817.4541150+$1809.0009250+$1800.5476500+$1792.0943
-
Category: Relays and accessoriesDescription: PKE Series of accessories for motor protection circuit breaker PKE, from trip block to fixed bracket### Moeller PKE Motor Protective Circuit Breakers73221+$1139.485610+$1129.126625+$1123.947250+$1118.7677100+$1113.5882150+$1108.4087250+$1103.2292500+$1098.0498
-
Category: Industrial Relay/UniversalDescription: EMR4 The professional Eaton current monitoring relay series comes from the EMR4 series. The main function of a relay is to monitor single-phase AC and DC networks. Relay design is used for a wide range of applications covering electrical switchgear technology, such as multifunctional 3-phase monitors and ground leakage monitors. Test button LED status indication # # # Eaton monitoring relay5835
-
Category: Industrial Relay/UniversalDescription: 星形三角形 - 开放式机架 开放式机架星形三角形启动器,在定制外壳中使用,允许快速简便安装和直接安装到 35mm DIN 导轨上。采用供货方便的 Moeller 部件制造,这些部件符合最新的 IEC 947 标准,并进行预接线以接受 Moeller Z00 或 ZB 热过载继电器(单相灵敏度符合 IEC 947-4)。星形三角形开放式机架启动器包含电源、三角形和星形接触器、星形三角形计时器(在 0 和 30 秒之间可调)和电路图表。 **没有提供**过载继电器,必须单独定购 制造商部件号以SDAINL**00AM**、**0M**、**0AM、1M**、SDAINL**M12**、**M16**、**M22**、**M30**、**M45**和 **M55**开头的部件使用 ZB12 和 ZB32 过载(典型库存号 493-1239) 端子保护等级 IP20 工作温度范围:-25 至 +40°C 7.5kW (SDAINL00AM) = 高 77 x 宽 162 x 深 112mm 12.5kW 和 18.5kW(SDAINL0M 和 SDAINL0AM)= 高 91 x 宽 162 x 深 117mm 22kW (SDAINL1M) = 高 98 x 宽 188 x 深 135mm 5.5 至 11kW(SDAINLM12 至 SDAINLM22)= 高 68 x 宽 158 x 深 125.2mm 15、22 和 30kW(SDAINLM30 至 SDAINLM55)= 高 85 x 宽 158 x 深 147.3mm ### 注 引用的 FLC 数字是最大值。 通过下列公式确定了规定过载:0.58 x 电动机 FLC。允许其他间隙尺寸,用于启动器上面和下面布线杆。热过载继电器 ZB12-16 当前缺货。 使用 X Start 系列部件的启动器不兼容 DILM 部件。 ### Moeller5734
-
Category: Industrial Relay/UniversalDescription: DILM 接触器,3 相 X Start 系列是 Moeller 最新一代接触器、过载和继电器,以经过尝试和试验的 DIL 系列为基础。 这一代模块化部件得益于电动机切换和控制技术的进步,从而为用户带来许多其它优点。 所有接触器均是模块化的,具有通用的设计 该系列极其耐用,能够处理所有需求,具有抗干扰功能和控制电路稳定性,即使在配合 PLC 使用时 磁场系统电子功率调节于直流接触器所需的框架尺寸非常小,这样可使交流和直流装置具有相同的尺寸。 这就允许直接把交流接触器和直流接触器相互并列放置。 三种常开主触点 12A 直流接触器具有一个电子驱动器,这样就无需耦合继电器,电流不超过 150A 的所有直流接触器都具有内置抑制电路 给不同截面布线时具有两个耦合区域的接线盒可保证连接的完整性,另外还可减少布线错误 ### Moeller X 开始范围9539
-
Category: Industrial Relay/UniversalDescription: DILM 接触器,3 相 X Start 系列是 Moeller 最新一代接触器、过载和继电器,以经过尝试和试验的 DIL 系列为基础。 这一代模块化部件得益于电动机切换和控制技术的进步,从而为用户带来许多其它优点。 所有接触器均是模块化的,具有通用的设计 该系列极其耐用,能够处理所有需求,具有抗干扰功能和控制电路稳定性,即使在配合 PLC 使用时 磁场系统电子功率调节于直流接触器所需的框架尺寸非常小,这样可使交流和直流装置具有相同的尺寸。 这就允许直接把交流接触器和直流接触器相互并列放置。 三种常开主触点 12A 直流接触器具有一个电子驱动器,这样就无需耦合继电器,电流不超过 150A 的所有直流接触器都具有内置抑制电路 给不同截面布线时具有两个耦合区域的接线盒可保证连接的完整性,另外还可减少布线错误 ### Moeller X 开始范围7467
-
Category: Industrial Relay/UniversalDescription: EATON MOELLER DILA-22(24V50HZ) 金属触芯, DPST-常开, DPST-常闭, DIN轨、面板安装, 240 V4785
-
Category: Industrial Relay/UniversalDescription: DILEEM / DILEM 小型接触器 这些装置可安装到 DIN 43 880 外壳中 表面安装或 DIN 卡轨安装 交流线圈功耗:5.4VA(连续);30VA(涌入) 直流线圈功耗:2.6W 触点最大额定电压 690V 交流 工作温度范围 -20 至 +50°C IP20 级端子保护/手指保护 尺寸:高 58 x 宽 45 x 深 52 mm ### 认可 CSA, ASE, SEV, UL, NEMKO, DEMKO, BV, RL, USSR, LROS, SEMKO ### Moeller DIL E 3 和 4 系列小型接触器和控制继电器8718
-
Category: Industrial Relay/UniversalDescription: DILA 接触器继电器 额定电流 4A AC15 ### 注 DILA - 22 接触器继电器不能与 4 极辅助触点模块一起使用。 ### Moeller X 开始范围7152
